Moderators: sobe, teracotix
-
ciobimar
- membru special
- Posts: 2686
- Joined: Wed Jun 27, 2012 12:18 am
-
Has thanked:
43 times
-
Been thanked:
12 times
Post
by ciobimar » Tue Apr 23, 2013 10:53 pm
Latest post of the previous page:
Da Dane ...trebuie sa fac asta ...sa vedem ..a zis orbul...
Am vanturat si eu aseara o gramada de pagini si gasisem ge toate ...si pompa de vid...
http://www.ebay.com/itm/A-C-Air-Vacuum- ... 3853119%26" onclick="window.open(this.href);return false;
Last edited by
ciobimar on Tue Apr 23, 2013 11:16 pm, edited 1 time in total.
-
phoenix
- senior
- Posts: 8346
- Joined: Sun Jun 24, 2012 9:43 pm
-
Has thanked:
0
-
Been thanked:
1 time
Post
by phoenix » Tue Apr 23, 2013 11:03 pm
Cu ce freon merg astea?
-
ciobimar
- membru special
- Posts: 2686
- Joined: Wed Jun 27, 2012 12:18 am
-
Has thanked:
43 times
-
Been thanked:
12 times
Post
by ciobimar » Tue Apr 23, 2013 11:23 pm
R 410A...o fi buna pompa aia ....din mesajul din urma...
-
ciobimar
- membru special
- Posts: 2686
- Joined: Wed Jun 27, 2012 12:18 am
-
Has thanked:
43 times
-
Been thanked:
12 times
Post
by ciobimar » Tue Apr 23, 2013 11:36 pm
Da cica e mai sigur sa faci instalarea cu pompa de vacum ,,,asa cum zici tu se poate si recupera din freon...si la scos tot aerul din instalatie inainte de a baga alt freon...
-
ciine
- membru
- Posts: 795
- Joined: Mon Jul 02, 2012 7:53 am
- Location: Valcea
-
Has thanked:
0
-
Been thanked:
0
-
Contact:
Post
by ciine » Wed Apr 24, 2013 8:54 am
Ceasurile sunt esentiale in montare si verificare presiunilor pe circuite cit si pt eventuala completare.
Aparatele noi au refrigerent R410 care e un amestec de mai multe componente , lucru rau intrucat nu permite competarea in cazul unei pierderi , deoarece coponentele au volatilitati diferite , asa ca in acest caz se face mai mult rau intrucat trebuie golita instalatia si reumpluta din nou .
-
phoenix
- senior
- Posts: 8346
- Joined: Sun Jun 24, 2012 9:43 pm
-
Has thanked:
0
-
Been thanked:
1 time
Post
by phoenix » Wed Apr 24, 2013 10:39 am
Nasol...alta inventie desteapta.
Marine in cazul asta ai nevoie de pompa :(
-
ciobimar
- membru special
- Posts: 2686
- Joined: Wed Jun 27, 2012 12:18 am
-
Has thanked:
43 times
-
Been thanked:
12 times
Post
by ciobimar » Wed Apr 24, 2013 11:15 am
Mai mult ca sigur ...Dane ..pompa de vid... butelie pentru freon ...ceasuri...tare mi-e frica ca..e posibil sa mai am vre-o unul fara freon...stiu ca asta vara ...imi mai facea unul ....un pic de gheata ...trebuie sa le iau la verificat...numai ca sau cam adunat cam multe in aceasta perioada ...fac si eu ce pot ...
-
flavius76
- SUPORT
- Posts: 2583
- Joined: Wed Jul 04, 2012 12:04 pm
-
Has thanked:
3 times
-
Been thanked:
33 times
Post
by flavius76 » Wed Apr 24, 2013 2:48 pm
In functionare ar trebui sa fie peste 5 bari pe conducta de joasa presiune(cea groasa), daca e sub 5 bari a mai pierdut din freon, asta e valabil pt R410A, masurarea se face cu AC pornit pe racire, caci in repaus presiunile din cele 2 circuite tind sa se egalizeze, rezultand o valoare mai mare la citire.
-
gi0
- senior
- Posts: 6952
- Joined: Sat Sep 15, 2012 11:22 pm
- Location: Constanta
-
Has thanked:
49 times
-
Been thanked:
40 times
-
Contact:
Post
by gi0 » Thu Jun 09, 2016 8:39 am
Buna ziua stimati domni .
As dori sa instalez doua aparate de aer conditionat , unul la bloc 9000-12000 btu si unul la casa 24000 btu .
Cred ca voi merge pe Gree .
Stiti o firma serioasa care vinde , instaleaza si asigura service in Constanta ?
Multumesc .
Cu stima .
-
CasaMeaEficienta
- membru
- Posts: 459
- Joined: Thu Jan 01, 2015 3:55 pm
-
Has thanked:
6 times
-
Been thanked:
6 times
Post
by CasaMeaEficienta » Mon Jul 11, 2016 9:54 pm
De obicei magazinele mari gen d.mo, a.tex, au firme agreate care monteaza aparatele altfel nu va ofera garantie.